UT6000A Specifications |
Click HERE to Download Brochure (PDF format).
Click HERE
to get Adobe Acrobat Free. |
 |
|
| Click on Picture to Enlarge |
|
| |
|
- 7" Color TFT Display
- 4 Channel Waveform Display
- 2 Channel ECG Real Time Display
- 600 Set Blood Pressure Data Storage and Recall
- 48 Hour Trend of SpO2/PR/RESP/HR/TEMP1/TEMP2
- Pacemaker Detection
- Apnea Alarm Function
- Applications from Adults to Neonates
- Central Station Networking Interface
- Internal Rechargeable Battery
- Built-in Thermal Recorder (Optional)
- Alarm Indicator Light
- Battery Recharging Indicator
- SAC, SpO2 (Optional)
|
| ECG |
|
| Heart Rate Range |
15-300bpm (±2bpm) |
| Lead Selection |
I, II, III, V, aVR, aVL, aVF |
| Lead Fault Alarm |
Audible / Visual |
| ECG Cable / Lead wire |
Standard |
| Sweep Speed |
12.5 / 25 / 50mm / S |
| Gain Selection |
x 4, x 2, x 1, x 0.5, x 0.25, Auto |
| Trend |
48 hours |
| ECG Calibration |
1mV |
| ST Range |
-0.8V to +0.8mV |
| Pulse Oximetry (SpO2) |
|
| Measure Range |
0-100% |
| SpO2 Averaging |
8-beat average |
| SpO2 Accuracy |
2% (70-100%), 3% (50-69%) |
| Pulse Rate Range |
30-254bpm |
| Sensor Types |
Finger clip, universal "Y", wrap, ear |
| Trends |
48 hours |
| Non-Invasive Blood Pressure (NIBP) |
|
| Method |
Automatic oscillometric |
| Parameters |
SYS / DIA / MAP / Pulse |
| Operating Modes |
Manual / Auto / Stat |
| Systolic Range |
Adult / Pediatric: 30-254mmHg (4.0-33.9kPa), Neonate: 30-135mmHg (4.0-18.0kPa) |
| Diastolic Range |
Adult / Pediatric: 10-220mmHg (1.3-29.3kPa), Neonate: 10-110mmHg (1.3-14.7kPa) |
| Tabular Trend |
600 groups |
| Temperature (TEMP) |
|
| Measurement and Alarm Range |
0-50°C |
| Channel |
Temp 1 and Temp 2 |
| Probe |
Skin or Esophageal / Rectal (Optional) |
| Scale |
Celsius / Fahrenheit |
| Accuracy |
±0.1°C |
| Resolution |
0.1°C |
| Trends |
48 hours |
| Respiration (RESP) |
|
| Measurement Method |
Thoracic impedance |
| Respiration Rate Range |
0-150brpm ±2brpm |
| Waveform Speed |
6.25, 12.5, 25mmm/sec |
| Trends |
48 hour |
| Safety Approval & Quality System |
|
| Safety Standard |
IEC 60601-1:1990 + A1:1993 + A2:1995 |
| Quality System |
ISO 9001 & EN 46001 & ISO 13485 Certified |
| Recorder |
|
| Type |
Built-in thermal array recorder |
| Printing Mode |
Real-time or alarm triggered |
| Resolution |
400dpi vertical, 800dpi horizontal |
| Annotation |
Time, date, vital sign readings |
| Power Supply |
|
| Power Supply |
110-230VAC, 50 / 60Hz, via power adapter |
| Input Power |
80VA |
| Battery |
DC 12V/2.2AH sealed lead-acid |
| Charge Time |
10 hours |
| Operating Time |
1.5 hours (when fully recharged |
| Physical Specifications |
|
| Net Weight |
3.5kg |
| Dimensions |
190H x 230W x 160D(mm) |