UT4000F Pro Specifications |
Click HERE to Download Brochure (PDF format).
Click HERE
to get Adobe Acrobat Free. |
 |
|
| Click on Picture to Enlarge |
|
| |
|
- 12.1" Color TFT Display
- Maximum 8 Channel Waveform Display
- 4 Channel ECG Waveform and Enlarged Waveform Display
- 120 Hour Graphic and Tabular Trend Information
- 600 Group Vital Sign Data Recall
- 12 Minute ECG Waveform Storage and Review
- ST Segment and Arrhythmia Analysis
- Pacemaker Detection
- Optional Cardiac Output and Multi-Gas Monitoring
- Networking Capability
- Bed to Bed View
- Applications from Adults to Neonates
- ECG/ST/ARRHYTHMIA/NIBP/SpO2/RESP/TEMP/IBP/CO2/RECORER
|
| ECG |
|
| Heart Rate Range |
15-300bpm |
| Lead Selection |
I, II, III, V, aVR, aVL, aVF |
| Lead Fault Alarm |
Audible / Visual |
| Sweep Speed |
12.5 / 25 / 50mm / S |
| Gain Selection |
x 4, x 2, x 1, x 0.5, x 0.25 |
| ECG Calibration |
1mV software generated |
| Protection |
Against electrosurgical interference and defibrillation |
| ST Segment Analysis |
-0.8V to +0.8mV |
| Arrhythmia Analysis |
13 types of arrhythmia identification (Optional) |
| ECG Waveform |
4 channel |
| NIBP |
|
| Method |
Automatic oscillometric |
| Parameters |
SYS / DIA / MAP |
| Operating Modes |
Manual / Auto / Stat (5 minutes) |
| Scale |
mmHg / kPa |
| Cuff Pressure Range |
Adult / Child: (0-300mmHg), Neonate: (0-150mmHg) |
| IBP (Optional) |
|
| Channel |
1 or 2 |
| Measurement Range |
-30 to +300mmHg |
| Resolution |
1mmHg |
| Sweep Speed |
6.25 / 12.5 / 25mm / S ± 10% |
| Transducer Sensitivity |
5uV / V / mmHg |
| Pulse Oximetry (SpO2) |
|
| Display |
Digit, waveform, pulse |
| Saturation Range |
0-100% (Adult / Child / Neonate) |
| Resolution |
1% |
| Accuracy |
± 2% (70-100%), ± 3% (50-69%) |
| Pulse Range |
30-254bpm |
| Accuracy |
± 1% (30-100bpm), ± 2% (>100bpm) |
| Respiration (RESP) |
|
| Method |
Impedance |
| Respiration Range |
0-150brpm |
| Accuracy |
±1brpm |
| Alarm |
User selectable alarm limits automatically kept in memory |
| Respiration Lead Selection |
RA-LA, RA-LL, LA-RL,RL-LL |
| Capnograph (CO2) (Optional) |
|
| Range |
0-99mmHg |
| Accuracy |
± 2mmHg (0-40mmHg), ± 5% (41-76mmHg), ± 10% (77-99mmHg) |
| Resolution |
1mmHg |
| Respiration Range |
0-150brpm ± 2brpm |
| Sweep Speed |
6.25 / 12.5 / 25mm / s ± 10% |
| Calibration |
Auto |
| Start-up Time |
<30 seconds |
| Temperature (Optional) |
|
| Channel |
2 |
| Display |
T1, T2, & change in T |
| Range |
0-50°C |
| Resolution |
0.1°C |
| Accuracy |
±0.1°C |
| Probe |
Skin or Esophageal / Rectal (Optional) |
| Recorder (Optional) |
|
| Recorder Type |
2 / 3 channel thermal recorder |
| Printing Mode |
Real-time or alarm triggered printing of waveform or text |
| Resolution |
X-axis: up to 800 dpi (32 dots / mm), Y-axis: 203 dpi (8dots / mm) |
| Annotation |
Date, time (24 hours) |
| Power Requirements |
|
| AC Input |
110-230VAC, 50 / 60Hz |
| Power Consumption |
<115VA |
| Battery |
12V 4AH sealed lead-acid, maintenance free |
| Battery Operating Time |
Approx. 2 hours when fully charged |
| Physical Specifications |
|
| Net Weight |
6.5kg |
| Gross Weight |
9kg |
| Dimensions |
250H x 320W x 170D(mm) |